Magnetic products
OWIHPPH_product
Description
Molded series with Plastic powder
Features
RoHS compliant
Lead-free materials used for the plating on the terminals
Metal terminals for excellent connection reliability
High resistance to heat, humidity, mechanical shocks and pressure.
Accurate dimensions for high precision mounting
Good heat durability that withstands lead-free compatible reflow soldering.
Applications
High reliability wire would chip inductors for communication equipment, instrumentation, video & audio. Developed with focus on higher density mounting of parts in electric circuits.
Characteristics
Test Voltage50mV
Parameters Test Temp25°C
Operation Temp (Incl temp rise)-40 to +125°C
Storage Temp0 to 40°C
Storage Humidity<70% RH
Resistance to Soldering Heat245°C for 10 sec
Rated Current40° typ. at Irms
Temperature rise

Request more info

Download as pdf

OWIHP453232PH - series

Plastic molded
Show all inductors in serie
Inductors:
OWIHP453232PH
Product ID
Inductance
DCR [mohm]
Isat [A]
Irms [A]
Test frequency
Q (min)
SRF [MHz]
Custom 1
Samples
Inductance
1.00 uH
DCR max:
0.11
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
180
Custom 1:
1050
samples visning
Inductance
1.20 uH
DCR max:
0.12
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
160
Custom 1:
1000
samples visning
Inductance
1.50 uH
DCR max:
0.15
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
130
Custom 1:
950
samples visning
Inductance
1.80 uH
DCR max:
0.16
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
100
Custom 1:
900
samples visning
Inductance
1.20 uH
DCR max:
0.18
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
80
Custom 1:
850
samples visning
Inductance
1.70 uH
DCR max:
0.20
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
60
Custom 1:
800
samples visning
Inductance
1.30 uH
DCR max:
0.22
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
45
Custom 1:
750
samples visning
Inductance
1.90 uH
DCR max:
0.24
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
40
Custom 1:
700
samples visning
Inductance
1.70 uH
DCR max:
0.27
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
35
Custom 1:
650
samples visning
Inductance
1.60 uH
DCR max:
0.30
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
30
Custom 1:
650
samples visning
Inductance
1.80 uH
DCR max:
0.35
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
28
Custom 1:
600
samples visning
Inductance
1.20 uH
DCR max:
0.40
IsatA table:
-
Irms A table
-
Test frequency:
7.96 MHz
Q min:
10
SRF [MHz] min:
25
Custom 1:
600
samples visning
Inductance
10.00 uH
DCR max:
0.50
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
22
Custom 1:
550
samples visning
Inductance
12.00 uH
DCR max:
0.60
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
21
Custom 1:
500
samples visning
Inductance
15.00 uH
DCR max:
0.70
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
20
Custom 1:
450
samples visning
Inductance
18.00 uH
DCR max:
0.80
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
19
Custom 1:
400
samples visning
Inductance
22.00 uH
DCR max:
0.90
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
18
Custom 1:
370
samples visning
Inductance
27.00 uH
DCR max:
1.20
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
16
Custom 1:
330
samples visning
Inductance
33.00 uH
DCR max:
1.40
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
14
Custom 1:
300
samples visning
Inductance
39.00 uH
DCR max:
1.60
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
12
Custom 1:
280
samples visning
Inductance
47.00 uH
DCR max:
1.90
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
11,5
Custom 1:
260
samples visning
Inductance
56.00 uH
DCR max:
2.20
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
11
Custom 1:
240
samples visning
Inductance
68.00 uH
DCR max:
2.60
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
10
Custom 1:
220
samples visning
Inductance
82.00 uH
DCR max:
3.50
IsatA table:
-
Irms A table
-
Test frequency:
2.52 MHz
Q min:
10
SRF [MHz] min:
9
Custom 1:
200
samples visning
Inductance
100.00 uH
DCR max:
4.00
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
8
Custom 1:
180
samples visning
Inductance
120.00 uH
DCR max:
4.50
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
7,5
Custom 1:
160
samples visning
Inductance
150.00 uH
DCR max:
6.50
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
7
Custom 1:
140
samples visning
Inductance
180.00 uH
DCR max:
7.50
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
6,5
Custom 1:
120
samples visning
Inductance
220.00 uH
DCR max:
9.00
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
5,5
Custom 1:
120
samples visning
Inductance
270.00 uH
DCR max:
11.00
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
5
Custom 1:
100
samples visning
Inductance
330.00 uH
DCR max:
13.00
IsatA table:
-
Irms A table
-
Test frequency:
0.796 MHz
Q min:
20
SRF [MHz] min:
4
Custom 1:
90
samples visning
Shape and dimensions [mm]
A
B
C
D
E
F
G
H
I
J
Shape
A:
4.50
A tol:
±0.4
B:
3.20
B tol:
±0.2
C:
3.20
C tol:
±0.2
D:
4.2
D tol:
±0.3
E:
1.1
E tol:
Ref
F:
1
F tol:
Ref
G:
G tol:
H:
1.3
H tol:
Ref
I:
1.4
I tol:
Ref
J:
2.2
J tol:
Ref
Shape:
Dimensions Image:
OWIHPPH_dimensions
PAD Image:
OWIHPPH_pad
Schematic Image:
OWIHPPH_schem
click images to enlarge
Ole Wolff Elektronik A/S | Roedengvej 14, 4180 Soroe, DK Denmark | +45 5783 3830 | sales@owolff.com